On Thursday 09 May 2013 18:20:59 Martin Schreiber wrote:
> On Thursday 09 May 2013 12:51:32 Med Hamza wrote:
> > Hi Martin,
> >   I think I am wrong, there is always a little problem ?
> >
> >   I have 2 tenumeditedit (e01,le02) wich share the same tifienumlinkcomp.
> >   when I input value to e01 I have the same value in e02 and the same
> > think when I input e02 ?
>
> Correct, that is how it works. There is one data point (the
> tifienumlinkcomp) and two GUI elements (e01,le02). The GUI elements are
> synchronised with the value of the datapoint. So if e01 changes the value
> le02 changes too.
>
Activate tifi*linkcomp.controller.optionsvalue vco_nosync in order to switch 
off data entry synchronization.
vcc_novaluetoclient switches off the propagation of setting the ifi controller 
value property.

Martin

------------------------------------------------------------------------------