On Thursday 09 May 2013 18:20:59 Martin Schreiber wrote: > On Thursday 09 May 2013 12:51:32 Med Hamza wrote: > > Hi Martin, > > I think I am wrong, there is always a little problem ? > > > > I have 2 tenumeditedit (e01,le02) wich share the same tifienumlinkcomp. > > when I input value to e01 I have the same value in e02 and the same > > think when I input e02 ? > > Correct, that is how it works. There is one data point (the > tifienumlinkcomp) and two GUI elements (e01,le02). The GUI elements are > synchronised with the value of the datapoint. So if e01 changes the value > le02 changes too. > Activate tifi*linkcomp.controller.optionsvalue vco_nosync in order to switch off data entry synchronization. vcc_novaluetoclient switches off the propagation of setting the ifi controller value property.
Martin ------------------------------------------------------------------------------ Learn Graph Databases - Download FREE O'Reilly Book "Graph Databases" is the definitive new guide to graph databases and their applications. This 200-page book is written by three acclaimed leaders in the field. The early access version is available now. Download your free book today! http://p.sf.net/sfu/neotech_d2d_may _______________________________________________ mseide-msegui-talk mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/mseide-msegui-talk