Am 30.11.2014 16:03, schrieb misu kun: > thanks > > do you mean application.beginhighrestimer() should be called inside > ontimer event ?
No, it can be done in oncreate or in main program before creating the forms. to_highres is on the way BTW. > if so , how do i get the counter value in microsecond , i mean which function? > or i should create an integer and increment it inside ontimer event ? > Yes, use an integer counter in ontimer. The interval has high precision apart from jitter. timestamp() from unit sysutils returns microseconds but also needs application.beginhighrestimer() on Windows in order to produce 1 ms jitter. Martin ------------------------------------------------------------------------------ Download BIRT iHub F-Type - The Free Enterprise-Grade BIRT Server from Actuate! Instantly Supercharge Your Business Reports and Dashboards with Interactivity, Sharing, Native Excel Exports, App Integration & more Get technology previously reserved for billion-dollar corporations, FREE http://pubads.g.doubleclick.net/gampad/clk?id=157005751&iu=/4140/ostg.clktrk _______________________________________________ mseide-msegui-talk mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/mseide-msegui-talk