[email protected] wrote:
Good Evening

I was attempting today to build and application using the latest msp-gcc from CVS using the MSP430X branch for the msp430x1611. When I compile, "Error: Extended instruction (bra) not allowed with msp430x1611 mcu" is reported. When the compiler is set to compile and not link, the final instruction in main is a "bra" instruction.
Thanks, fixed.

This remains despite using -mmcu=msp430x1611 and the -mdata-64k option.
Please do not use -mdata-64k option with non-430X, as it causes linking wrong 
(non-hwmul) libraries.

--
Regards,
   Sergey A. Borshch            mailto: [email protected]
     SB ELDI ltd. Riga, Latvia