>> Does anybody have info about PHYDIO routine? I know, what I must input to
>The exit code of the PHYDIO routine is CARRY FLAG and register A. If carry
>flag is reset, the operation was successfully completed. Else, register A
>will have an error code. I don't know the error codes, but if you do some
>tests, you can easily detect the write-protection detected code.
0 = Write protected
2 = Not ready
4 = Data error
6 = Seek error
8 = Record not found
10 = Write error
12 = Bad parameter
14 = Out of memory
16 = Other error
Remember that you can download MSX2 Technical Handbook from my home page... 8-)
-------------------------------------------------------
Konami Man - AKA Nestor Soriano (^ ^)Y
[EMAIL PROTECTED]
http://www.geocities.com/SiliconValley/Bay/9797/msx.htm
This Pentium will become obsolete in 5 seconds...
4... 3... 2...
-------------------------------------------------------
****
MSX Mailinglist. To unsubscribe, send an email to [EMAIL PROTECTED] and put
in the body (not subject) "unsubscribe msx [EMAIL PROTECTED]" (without the
quotes :-) Problems? contact [EMAIL PROTECTED] (www.stack.nl/~wiebe/mailinglist/)
****