The SL45 does not support IrMC synchronization, only IrMC
getting/putting. Therefore, when MultiSync tries to fetch the change
log, the phone answers with the first entry. 

So, there is no use trying more :-(

/Bo

On Thu, 2003-07-31 at 16:14, Sameer Morar wrote:
> Hi All
> 
> I have just installed the latest debian cvs snapshots of multisync, and
> am testing it with my Siemens SL45 phone and Evolution 1.4.
> 
> I have enabled the MULTISYNC_DEBUG environment varaible, and here's my
> output.
> 
> I know that ppl have tried the Siemens S45, and it doesn't work,
> however, this output below shows that something is working with the
> SL45. Anyone had any success with the SL45 phone?
> 
> Trying /usr/lib/multisync/libirmc_sync.so...
> Plugin found: Mobile Device (IrMC) client
> Trying /usr/lib/multisync/libldap_plugin.so...
> Plugin found: LDAP MultiSync plugin
> Trying /usr/lib/multisync/libbackup_plugin.so...
> Plugin found: Backup plugin
> Trying /usr/lib/multisync/libevolution_sync.so...
> Detected evolution 1.4.
> Plugin found: Ximian Evolution client
> Trying /usr/lib/multisync/libirmc_bluetooth.so...
> Found pair: irmc-sync - evolution-sync
> Get view done.
> Loaded change counter 0
> Loaded change counter 0
> Found no IR devices.
> Searching for units...
> Got message 0
> Loaded change counter 0
> Loaded change counter 0
> Get changes done.
> New DBs: 0
> Change log:
> BEGIN:VCARD
> VERSION:1.0
> REV:20030217T094710
> N:Joe;Bloggs
> TEL;HOME:+277777777
> END:VCARD
>  
> Get cc failed.
> Searching for units...
> Got message 0
> Loaded change counter 0
> Loaded change counter 0
> Searching for units...
> Got message 0
> Loaded change counter 0
> Loaded change counter 0
> Found no IR devices.
> Searching for units...
> 
> Here, clearly only one vcard comes through, although there are more than
> this on my phone.
> 
> Nothing else happens, and when I look at my phone, it not in the the
> Infra red mode anymore.
> 
> I have to remove my phone battery and turn it back on again (ie, just
> turning on ir again doesn't work) for Multisync to see it at all again,
> and this happens every time.
> 
> Anyone know what's wrong?  I do know that the Siemens SL45 doesn't
> support data compression for transferring over Infra red. Could this
> cause the ir daemon on the phone to die?
> 
> I'm willing to poke around in the code to get this working, I just need
> to know where to start, and what kind of things to try.
> 
> Thanks
> Sam
-- 
Bo Lincoln <[EMAIL PROTECTED]>



-------------------------------------------------------
This SF.Net email sponsored by: Free pre-built ASP.NET sites including
Data Reports, E-commerce, Portals, and Forums are available now.
Download today and enter to win an XBOX or Visual Studio .NET.
http://aspnet.click-url.com/go/psa00100003ave/direct;at.aspnet_072303_01/01
_______________________________________________
Multisync-users mailing list
[EMAIL PROTECTED]
https://lists.sourceforge.net/lists/listinfo/multisync-users

Reply via email to