The SL45 does not support IrMC synchronization, only IrMC getting/putting. Therefore, when MultiSync tries to fetch the change log, the phone answers with the first entry.
So, there is no use trying more :-( /Bo On Thu, 2003-07-31 at 16:14, Sameer Morar wrote: > Hi All > > I have just installed the latest debian cvs snapshots of multisync, and > am testing it with my Siemens SL45 phone and Evolution 1.4. > > I have enabled the MULTISYNC_DEBUG environment varaible, and here's my > output. > > I know that ppl have tried the Siemens S45, and it doesn't work, > however, this output below shows that something is working with the > SL45. Anyone had any success with the SL45 phone? > > Trying /usr/lib/multisync/libirmc_sync.so... > Plugin found: Mobile Device (IrMC) client > Trying /usr/lib/multisync/libldap_plugin.so... > Plugin found: LDAP MultiSync plugin > Trying /usr/lib/multisync/libbackup_plugin.so... > Plugin found: Backup plugin > Trying /usr/lib/multisync/libevolution_sync.so... > Detected evolution 1.4. > Plugin found: Ximian Evolution client > Trying /usr/lib/multisync/libirmc_bluetooth.so... > Found pair: irmc-sync - evolution-sync > Get view done. > Loaded change counter 0 > Loaded change counter 0 > Found no IR devices. > Searching for units... > Got message 0 > Loaded change counter 0 > Loaded change counter 0 > Get changes done. > New DBs: 0 > Change log: > BEGIN:VCARD > VERSION:1.0 > REV:20030217T094710 > N:Joe;Bloggs > TEL;HOME:+277777777 > END:VCARD > > Get cc failed. > Searching for units... > Got message 0 > Loaded change counter 0 > Loaded change counter 0 > Searching for units... > Got message 0 > Loaded change counter 0 > Loaded change counter 0 > Found no IR devices. > Searching for units... > > Here, clearly only one vcard comes through, although there are more than > this on my phone. > > Nothing else happens, and when I look at my phone, it not in the the > Infra red mode anymore. > > I have to remove my phone battery and turn it back on again (ie, just > turning on ir again doesn't work) for Multisync to see it at all again, > and this happens every time. > > Anyone know what's wrong? I do know that the Siemens SL45 doesn't > support data compression for transferring over Infra red. Could this > cause the ir daemon on the phone to die? > > I'm willing to poke around in the code to get this working, I just need > to know where to start, and what kind of things to try. > > Thanks > Sam -- Bo Lincoln <[EMAIL PROTECTED]> ------------------------------------------------------- This SF.Net email sponsored by: Free pre-built ASP.NET sites including Data Reports, E-commerce, Portals, and Forums are available now. Download today and enter to win an XBOX or Visual Studio .NET. http://aspnet.click-url.com/go/psa00100003ave/direct;at.aspnet_072303_01/01 _______________________________________________ Multisync-users mailing list [EMAIL PROTECTED] https://lists.sourceforge.net/lists/listinfo/multisync-users