You need to get the reflex 72 driver (Which is really the SCR-131 driver) from the SCM Microsystems web site at:
ftp://ftp.scmmicro.com/security/drivers/scr131_Solaris_alpha.tar.gz
... As the slb rf72 v. 1.1.0 driver won't work.
Then make sure you have symlinks set as follows:
Symlink
/dev/pcsc/1 -> /dev/cua/a
/dev/pcsc/2 -> /dev/cua/b
Then set the reader.conf to either CHANNELID 0x000001 or 0x000002 (respectively)
Hope this helps.
-- Tammy
At 11:19 AM 1/14/2003 -0500, you wrote:
When trying to start pcscd on a sun blade 100 with the following:
solaris 8 (sparc)
reflex 72 serial reader - powered by 4 AA batteries (since the sun blade does not have ps/2 ports)
I get the following error:
# ./pcscd -d stdout
pcscdaemon.c:258 main: debug messages to stdout
readerfactory.c:1318 RFInitializeReader: Attempting startup of Schlumberger Reflex 72 0 0.
readerfactory.c:1060 RFBindFunctions: Loading IFD Handler 2.0
--> 12 0 6 0 d0 0 15 1 0 d0
<--
readerfactory.c:1355 RFInitializeReader: Open Port 103F8 Failed
readerfactory.c:1190 RFUnloadReader: Unloading reader driver.
readerfactory.c:219 RFAddReader: Schlumberger Reflex 72 init failed.
pcscdaemon.c:413 main: pcsc-lite daemon ready.
The contents of reader.conf:
FRIENDLYNAME "Schlumberger Reflex 72"
DEVICENAME GEN_SMART_RDR
LIBPATH /usr/local/pcsc/drivers/slb_rf72/libslb_rf72.so
CHANNELID 0x0103F8
I've tried changing the CHANNELID to 0x0102F8, as well as 0x000001, or
playing with the serial port configuration using admintool. Nothing works.
Has anyone had a similar problem, or know what might be causing the error?
Thanks for your help...
================================================== Tammy M. Blaser NASA John H. Glenn Research Center Flight Software Engineering Organization 7750 Mail stop 86-11 216-433-2699 (office) 216-433-8269 (fax) [EMAIL PROTECTED] ==================================================
_______________________________________________ Muscle mailing list [EMAIL PROTECTED] http://lists.musclecard.com/mailman/listinfo/muscle