Hi list,
I can't make clear on this case:
1. A ccid reader with max_packet_length = 20;
2. Host send a case 2 APDU to ICC which Ne = 10;
3. Since ICC has lots of data to send back, he indicated a new value in
SW1-SW2= 6C30;

As ISO7816-3 said, when received 6CXY, we need use this SW2 in next
command which is modified from previous APDU command.

There is a problem I, the reader cannot accept this I thought(his
max_recv length is 20 only). Who can give me some hints?

After some test I found that, ICC can receive the command with other
value if it can handle after it sent 6CXY. But I'm not sure is this
whether applied the standard and is it a normal way?

Thanks

--
zeal

_______________________________________________
Muscle mailing list
[email protected]
http://lists.drizzle.com/mailman/listinfo/muscle