2011/9/8 Umberto Rustichelli aka Ubi <[email protected]>:
> Dear all,

Hello,

> I'm not an expert of smart card readers nor of APDU commands but I'm
> developing software that uses a mix of PKCS#11 modules since some time.
> I gave a look to proto-t1.c but for sure you cannot guess the real meaning
> of the error without sufficient background.
>
> Using a new smart card reader, I'm experiencing some slowdown in
> communication with the smart cards and I see this error in the logs:
>
> proto-t1.c:479:t1_transceive() CT sent S-block with wtx=1
>
> As the operations are completed anyway, so I guess this is rather a sort of
> warning, but what does it mean (in human terms)?
> Is there some issue in the communication and the driver must cope with it by
> resending data (hence the slight slowdown)?
>
> I'm currently forced to use old versions of the software involved (see
> later), so the second question is: should I care about the error? What could
> the consequenses be?

It is not an error nor a warning. It is a debug information line.
It just says "The card asked for more time. Please wait.".

Sébastien gave a more exact (but maybe less human friendly :-) answer.

Bye

-- 
 Dr. Ludovic Rousseau

_______________________________________________
Muscle mailing list
[email protected]
http://lists.drizzle.com/mailman/listinfo/muscle

Reply via email to