Hello - was this problem ever resolved? I am having the same issue. It seems
to occur on both Mac and PC versions (at least). I'm running the latest build
(2.4) of MZmine.
Thanks,
Lee
Hi Julian,
Can you provide a sample MZmine project where we can reproduce the problem?
Tomas
On Oct 12, 2011, at 12:42 AM, Julian Kang wrote:
> Hi,
>
> When I deconvolute the chromatogram using the Savitzky-Golay filter, it
> returns several peaks with zero values for m/z regardless of what percentage
> I use under the parameters. Is there any way to avoid this? Thanks for your
> help!
>
> -Julian
>
> --
> Cornell University
> Class of 2010
> B.A. in Chemistry
>
>
> ------------------------------------------------------------------------------
> All the data continuously generated in your IT infrastructure contains a
> definitive record of customers, application performance, security
> threats, fraudulent activity and more. Splunk takes this data and makes
> sense of it. Business sense. IT sense. Common sense.
> http://p.sf.net/sfu/splunk-d2d-oct_______________________________________________
> Mzmine-devel mailing list
> Mzmine-devel@...
> https://lists.sourceforge.net/lists/listinfo/mzmine-devel
===============================================
Tomas Pluskal
G0 Cell Unit, Okinawa Institute of Science and Technology
1919-1 Tancha, Onna-son, Okinawa 904-0495, Japan
TEL: +81-98-966-8684
------------------------------------------------------------------------------
All the data continuously generated in your IT infrastructure
contains a definitive record of customers, application performance,
security threats, fraudulent activity, and more. Splunk takes this
data and makes sense of it. IT sense. And common sense.
http://p.sf.net/sfu/splunk-novd2d
_______________________________________________
Mzmine-devel mailing list
Mzmine-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/mzmine-devel