My SMB boards arrived yesterday. 
Thank Todd, for that perfect service.
I have it up and it is running at once without problems.
My first object to monitoring is a Jade Big Z based computer.
The SMB shows the correct data, but the address allways stay at 000000.
I find that the address latch logic neede a valid pSTVAL signal.
The JADE board have instead PHI1 connected to pin 25, which i have cutted.
Any thougth for building a vald pSTVAL signal?

Frank

-- 