*System hardware:*

Compupro CPUZ, Compupro Ram17, Compupro System Support 1, Dual IDE CF card 
(A: and B:), ZFDC card with 5.25" drive C:

I built my dual IDE card earlier this year and have a very reliable 
‘no-holes’ system running from CF cards.   

I have now finished the ZFDC board and can use it with either 3.5” or 5.25” 
floppy drives reliably with the ZFDCDIAG program. 

When I boot CPM from the CF card it initializes the ZFDC board with no 
errors. 

*I can not, however, access drive C: and D: from CPM*

When I enter "A>C:" I see the following: ZFDC board display shows 'FF3B0' 
and Halt led comes on.  

*On the console it displays:* 

*Floppy Disk drive Login Error (door open?)*

*ZFDC Board Sector Read Error*

*Bios Error on C: T-00001, S-00000*

*ZFDC Board Error Code =FFH   *

 The Halt led clears and the ZFDC board returns to display FF000

I get the A> back on the console

Need some suggestions as to what I may be missing from my code (system) - 
thanks in advance.


 So, in my CPM3.sys file I have the following:  

 *HIDE3.asm*

            PUBLIC DPH0, DPH1                   ;DISK PARAMETER HEADERS 
drive A and B

            …

            ; EXTENDED DISK PARAMETER HEADER FOR DRIVE 0:

       DW     HDWRT         ;HARD DISK WRITE ROUTINE

       DW     HDRD          ;HARD DISK READ ROUTINE

       DW     HDLOGIN$0     ;HARD DISK LOGIN PROCEDURE

       DW     HDINIT$0      ;HARD DISK DRIVE INITIALIZATION ROUTINE

       DB     0             ;RELATIVE DRIVE 0 ON THIS CONTROLLER

       DB     0             ;MEDIA TYPE:

                             ;HI BIT SET : DRIVE NEEDS RECALIBRATING

DPH0:  DPH    0,IDEHD$DPB,0,

       DB     0             ;Drive A: Hardware Select, (IX offset 25)

 

       ; EXTENDED DISK PARAMETER HEADER FOR DRIVE 1:

       DW     HDWRT         ;HARD DISK WRITE ROUTINE

       DW     HDRD          ;HARD DISK READ ROUTINE

       DW     HDLOGIN$1     ;HARD DISK LOGIN PROCEDURE

       DW     HDINIT$1      ;HARD DISK DRIVE INITIALIZATION ROUTINE

       DB     0                     ;RELATIVE DRIVE 0 ON THIS CONTROLLER

       DB     0                     ;MEDIA TYPE:

                                    ;  HI BIT SET : DRIVE NEEDS 
RECALIBRATING

DPH1:  DPH    0,IDEHD$DPB,0,

       DB     1                     ;Drive B: Hardware Select, (IX offset 
25)

 

   *HDRVTBL3.asm*

            EXTRN  DPH0,DPH1,DPH2,DPH3

       …

        @DTBL: DTBL   <DPH0,DPH1,DPH2,DPH3,0,0,0,0,0,0,0,0,0,0,0,0>

 

 *HFL3.asm*

            PUBLIC DPH2,DPH3                    ;FLOPPY DISK PARAMETER 
HEADERS

       …

        ; First 5 1/4" DRIVE

        ; EXTENDED DISK PARAMETER HEADER FOR DRIVE 2: (C:)

       DW     WRITE$SECTOR          ;FD SEC WRITE ROUTINE

       DW     READ$SECTOR                  ;FD SEC READ ROUTINE

       DW     FLOPPY$LOGIN$0 ;FLOPPY DISK "C:" LOGIN PROCEDURE

       DW     FLOPPY$INIT$0         ;FLOPPY DISK "C:" DRIVE INITIALIZATION 
ROUTINE

       DB     0                     ;RELATIVE DRIVE 0 ON THIS CONTROLLER

       DB     MINCPM                ;CPM-86 5" DDDS Disk

                                    ;HI BIT SET : DRIVE NEEDS RECALIBRATING

DPH2:  DPH    DD512$trans,MINI$dpb,,

                                    ;Bytes 0-24 used by DPH/CPM

       DW     512                   ;25, 512 Bytes per sector count

       DB     0                     ;27, Drive Hardware Select

 

 ; Second 5 1/4" DRIVE        

        ; EXTENDED DISK PARAMETER HEADER FOR DRIVE 3: (D:)

       DW     WRITE$SECTOR          ;FD SEC WRITE ROUTINE

       DW     READ$SECTOR           ;FD SEC READ ROUTINE

       DW     FLOPPY$LOGIN$1 ;FLOPPY DISK "D:" LOGIN PROCEDURE

       DW     FLOPPY$INIT$1         ;FLOPPY DISK "D:" DRIVE INITIALIZATION 
ROUTINE

       DB     0                     ;RELATIVE DRIVE 0 ON THIS CONTROLLER

       DB     MINCPM                ;CPM-86 5" DDDS Disk

                                    ;HI BIT SET : DRIVE NEEDS RECALIBRATING

DPH3:  DPH    DD512$trans,MINI$dpb,,

                                    ;Bytes 0-24 used by DPH/CPM

       DW     512                   ;25, 512 Bytes per sector count