Greetings,
I was wondering if anyone had found the proper way to modify nrpe to receive
more than the 1024 character limit imposed in MAX_PACKETBUFFER_LENGTH. I
adjusted it from 1024 to 1536 and have used this setting for quite some time
now and it works; however, graceful connection shutdowns are not possible
when using this modification.
It appears that nrpe tries to send all data in just a single packet. Is
there a reason that multiple packets aren't used if the packet buffer isn't
large enough to accommodate all of the plugin output? I could see this
being especially troublesome for Nagios 3.0 as the buffer will be too small
to fully take advantage of multiline output.
Regards,
Mike
-------------------------------------------------------------------------