On Feb 25, 12:03pm, Alex Bligh <[EMAIL PROTECTED]> wrote: > One circumstance where this does work is connecting (for instance) an E1 > trunk connection between (say) two FR switches in the same room, provided > you remember to set exactly one end to originate, and one end to receive > clock (i.e. where there are no carriers involved).
Fair enough. Pin-out is not the same as ethernet, but same idea; there's a very clear diagram here about 2/3s down the page: http://www.nettonet.com/support/docs/220-0000081_r01.n2n -- Per