Ya not wishing to do NAT...

Sent from mobile device..

________________________________
From: Alex Conner <[email protected]>
Sent: Thursday, June 10, 2021 1:49:27 PM
To: TJ Trout <[email protected]>
Cc: Dennis Burgess <[email protected]>; [email protected] <[email protected]>
Subject: Re: AT&T Fiber Line / NOT MIS

Bonus points, the small business fiber has extremely limited NAT session limits 
(depends on hardware, but not greater than 16,000 sessions) and everything 
counts. Cold loading CNN.com (an AT&T company) in a default config without an 
adblocker will use close to 3000, which will saturate and cause errors on some 
of their gateway hardware (NVG595). If you want to use it for any serious 
purpose, stick a tunnel out to a real connection.

On Thu, Jun 10, 2021 at 2:43 PM TJ Trout 
<[email protected]<mailto:[email protected]>> wrote:
Yeah not going to happen on U-verse

On Thu, Jun 10, 2021 at 11:32 AM Dennis Burgess 
<[email protected]<mailto:[email protected]>> wrote:

Guess their broadband stuff☹





[LTI-Full_175px]

Dennis Burgess

Author of "Learn RouterOS- Second Edition”

Link Technologies, Inc -- Mikrotik & WISP Support Services

Office: 314-735-0270  Website: 
http://www.linktechs.net<http://www.linktechs.net/>

Create Wireless Coverage’s with 
www.towercoverage.com<http://www.towercoverage.com>

Need MikroTik Cloud Management: https://cloud.linktechs.net



From: TJ Trout <[email protected]<mailto:[email protected]>>
Sent: Thursday, June 10, 2021 1:12 PM
To: Dennis Burgess <[email protected]<mailto:[email protected]>>
Cc: [email protected]<mailto:[email protected]>
Subject: Re: AT&T Fiber Line / NOT MIS



call back, i dont think that's accurate. What is the specific product?



On Thu, Jun 10, 2021 at 7:25 AM Dennis Burgess 
<[email protected]<mailto:[email protected]>> wrote:

I have a ATT fiber line for a customer that has a 300/300 circuit, but its not 
a MIS they are telling me we cannot route a /26 (they have allocated) to my 
device behind it.  ☹  Any options?





Dennis Burgess

Mikrotik : Trainer, Network Associate, Routing Engineer, Wireless Engineer, 
Traffic Control Engineer, Inter-Networking Engineer, Security Engineer, 
Enterprise Wireless Engineer

Hurricane Electric: IPv6 Sage Level

Cambium: ePMP



Author of "Learn RouterOS- Second Edition”

Link Technologies, Inc -- Mikrotik & WISP Support Services

Office: 314-735-0270  Website: 
http://www.linktechs.net<http://www.linktechs.net/>

Create Wireless Coverage’s with 
www.towercoverage.com<http://www.towercoverage.com>

Need MikroTik Cloud Management: https://cloud.linktechs.net

How did we do today?

<https://app.customerthermometer.com/?template=log_feedback&hash=5badbac1&embed_data=dGVtcGVyYXR1cmVfaWQ9MSZ0aGVybW9tZXRlcl9pZD0xMTM1NjYmbnBzX3JhdGluZz0tMQ==&e=Anonymous&f=Dennis&l=Burgess&c=&c1=&c2=&c3=&c4=&c5=&c6=&c7=&c8=&c9=&c10=>


Reply via email to