Hello NANOG,

We are currently in the process of rolling out a Motorola GPON solution and 
running into some hiccups and wanted to see if we were doing something unique 
or if anyone else has run into the issue and we just haven't found the right 
solution.

Our configuration has the OLTs using single tagged VLANs down to each customer 
ONT, rather than using Q in Q connections. This VLAN is shared among all 
customers that terminate at a single site, which may have 1-2 OLTs sharing that 
same VLAN. This VLAN is then carried back via switching to our core equipment 
which handles routing. We have noticed that malfunctioning customer equipment 
have generated loops on the network which has caused unusual forwarding 
problems in the OLT, and many of the ONTs we are in the process of deploying, 
1400GTI, don't include the ability to detect these loops.

If anyone wants more information feel free to follow up with me off list. We 
are hoping we aren't the only ones attempting this and can find a sane solution 
to the issue.

Josh Hoppes
Cedar Falls Utilities


Reply via email to