----- Original Message ----- > From: "Saku Ytti" <s...@ytti.fi>
> > In the architecture I described, though, is it really true that the > > odds of the common types of failure are higher than with only one? > > I think so, lets assume arbitrarily that probability of NTP server not > starting to give incorrect time is 99% over 1 year time. > Then either of two servers not giving incorrect time is 0.99**2 i.e. 98%, so > two NTP servers would be 1% point more likely to give incorrect time than one > over 1 year time. That's only true if the two devices have common failure modes, though, is it not? -- Jay R. Ashworth Baylink j...@baylink.com Designer The Things I Think RFC 2100 Ashworth & Associates http://www.bcp38.info 2000 Land Rover DII St Petersburg FL USA BCP38: Ask For It By Name! +1 727 647 1274