A few years ago I did some testing and found that the time between the 
transceiver detecting LOS and the routing protocol (ISIS in this case) being 
informed that the link was down (triggering the recalculation) took longer than 
it took BFD to signal ISIS to recalculate.

> On Mar 21, 2018, at 12:35 PM, Bryan Holloway <br...@shout.net> wrote:
> 
> Wouldn't any tangible problem on a dark-fiber link result in an interface 
> shutdown, ostensibly creating the trigger one would need to begin 
> re-convergence?
> 
> 
> On 3/21/18 11:31 AM, Alex Lembesis wrote:
>> To speed up BGP routing convergence.  The (2x) dark fiber links from PA to 
>> FL are being used as Layer3 datacenter interconnects, where each datacenter 
>> has its own AS.  The DF is also carrying FCIP traffic, so we need failover 
>> to be as fast as possible.
>> Best regards,
>> Alex
>> -----Original Message-----
>> From: Job Snijders (External) [mailto:j...@instituut.net]
>> Sent: Wednesday, March 21, 2018 12:25 PM
>> To: Youssef Bengelloun-Zahr
>> Cc: Alex Lembesis; NANOG
>> Subject: Re: How are you configuring BFD timers?
>> Silly question perhaps, but why would you do BFD on dark fiber?
>> Kind regards,
>> Job