Dear Wolfgang,
I found an explanation: probably you have indeed no legacy defer
callbacks registered, but NaviServer does an UpdateInterp() even when no
defer callbacks were executed, which might have changed the state.
During UpdateInterp() it probably re-evaluates the "namespace eval
::WS::Utils {...}", which complains, since tdom rejects to reset "its"
variable. I wonder, whether this is the only place, where the
interaction between tclws & tdom & interp updates can cause complaints.
Anyhow, the change [1] omits the update of the interpreter, when nothing
could have been changed by the defer callbacks. It should be as well
performance-wise better.
Hope this helps
-g
https://bitbucket.org/naviserver/naviserver/commits/526312b7ac23f734f0002d3d1514025dfb4ea36e
Am 21.10.16 um 07:59 schrieb Wolfgang Winkler:
We are using
ns_param nssock ${bindir}/nssock.so
ns_param nslog ${bindir}/nslog.so
ns_param nsdb ${bindir}/nsdb.so
ns_param nscp ${bindir}/nscp.so
ns_param nsproxy ${bindir}/nsproxy.so
ns_param postgres "${bindir}/nsdbpg.so"
I tried to uncomment them, but the error is still there.
I've grepped through all our sources but did not find a call to
Ns_TclRegisterDeferred, ns_ictl cleanup or ns_cleanup.
Am 2016-10-20 um 17:18 schrieb Gustaf Neumann:
sure. but the point is, this call does on usual installations
nothing, .... unless someone registers a function with
Ns_TclRegisterDeferred().
What modules are you loading?
-g
Am 20.10.16 um 16:53 schrieb Wolfgang Winkler:
ns_ictl cleanup is called from ns_cleanup in
naviserver/bin/init.tcl. When I remove the call, the error goes way.
These are the relevant calls:
ns_ictl trace deallocate ns_cleanup
proc ns_cleanup {} {
ns_cleanupchans; # Close files
ns_cleanupvars; # Destroy global variables
ns_set cleanup; # Destroy non-shared sets
ns_http cleanup; # Abort any http requests
#ns_ictl cleanup; # Run depreciated 1-shot Ns_TclRegisterDefer's.
}
regards,
Wolfgang
Am 2016-10-20 um 16:26 schrieb Gustaf Neumann:
Hmm, it looks to me, as if this error is triggered not from the
startup, but from the shutdown.
The backtrace shows, that "ns_ictl cleanup" is causing this, which
in turn calls the callbacks registered with
Ns_TclRegisterDeferred(), which is a deprecated function (since
many years). Ns_TclRegisterDeferred() is nowhere called within
NaviServer, so it looks to me that you might have c-based module in
use, which calls this function.... is this correct?
Aside form the strange situation around "ns_ictl cleanup", the
error was probably triggered in earlier versions of NaviServer as
well, but in some newer versions of NaviServer, error conditions,
which were silently swallowed before, are now reported back to the
user.
The message "var is read-only" is actually generated by tDOM. It
might be the case, that the function registered via
Ns_TclRegisterDeferred() either sources Utilities.tcl (from tclws),
or it might re-evaluate the blueprint during shutdown; both is
probably not wanted.
Hope this helps
-g
Am 20.10.16 um 10:25 schrieb Wolfgang Winkler:
Hi!
We are using webservices for tcl (tclws) with naviserver. For
naviserver version 4.99.7 we sometimes get the following error
message:
Error: can't set "xsltSchemaDom": var is read-only
var is read-only
(write trace on "xsltSchemaDom")
invoked from within
"variable xsltSchemaDom domDoc0xa7c640"
(in namespace eval "::WS::Utils" script line 3)
invoked from within
"namespace eval ::WS::Utils {
variable currentNs {}
variable xsltSchemaDom domDoc0xa7c640
variable standardAttributes {
baseType
comme..."
invoked from within
"ns_ictl cleanup"
(procedure "ns_cleanup" line 6)
invoked from within
"ns_cleanup"
while executing callback
ns:tcltrace ns_cleanup
(context: trace proc)
With version 4.99.13 we get his error on every startup. It seems
to be connected to thread creation. Has anybody any idea how to
prevent this error?
regards,
Wolfgang
--
*Wolfgang Winkler*
Geschäftsführung
wolfgang.wink...@digital-concepts.com
mobil +43.699.19971172
dc:*büro*
digital concepts Novak Winkler OG
Software & Design
Landstraße 68, 5. Stock, 4020 Linz
www.digital-concepts.com <http://www.digital-concepts.com>
tel +43.732.997117.72
tel +43.699.1997117.2
Firmenbuchnummer: 192003h
Firmenbuchgericht: Landesgericht Linz
------------------------------------------------------------------------------
Check out the vibrant tech community on one of the world's most
engaging tech sites, SlashDot.org!http://sdm.link/slashdot
_______________________________________________
naviserver-devel mailing list
naviserver-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/naviserver-devel
--
*Wolfgang Winkler*
Geschäftsführung
wolfgang.wink...@digital-concepts.com
mobil +43.699.19971172
dc:*büro*
digital concepts Novak Winkler OG
Software & Design
Landstraße 68, 5. Stock, 4020 Linz
www.digital-concepts.com <http://www.digital-concepts.com>
tel +43.732.997117.72
tel +43.699.1997117.2
Firmenbuchnummer: 192003h
Firmenbuchgericht: Landesgericht Linz
------------------------------------------------------------------------------
Check out the vibrant tech community on one of the world's most
engaging tech sites, SlashDot.org! http://sdm.link/slashdot
_______________________________________________
naviserver-devel mailing list
naviserver-devel@lists.sourceforge.net