Did you get any responses to your question? What part of the math didn't work out?
On Wed, 20 Sep 2000 16:06:23 -0700, David Spencer <[email protected]> wrote: >I am working out a test plan for the magnetic field requirements in GR1089 >3.2.2 and noticed that the math didn't work when I started figuring the >dBuA/m for a 10 meter site. This is kind of a duh question, but am I >correct in assuming that we need to do the H fields at 3 meters? If someone >wouldn't mind sharing the distances they use for this test, I would be most >grateful. >Thanks, >Dave Spencer Compliance Engineer >Oresis Communications, Inc. >14670 NW Greenbrier Parkway, Beaverton, OR 97006 >* [email protected] * http://www.oresis.com >* (503) 466-6289 * (503) 533-8233