| I just discovered the GTE175M and GDE120T are unsuitable, | because the datasheets say the first only can manage frequencies | up to 1kHz and the second has a ionisation time of 1 ms and a | deionisation time of 5 ms.
| EZ10B but it is available and fit for 1 MHz. Yeah, cold cathode gas triggers are pretty slow, so are most cold cathode tubes. Its pretty amazing that they got the EZ10B upto 1MHz. A krytron may work, if you can get your hands on one. A more realistic option, is to use a common vacuum tube (ECC82/12AU7, or ECC91/6J6). The 6J6 was designed for RF & IF apps, so switching at 1MHz is not a problem for that tube, and they sell for dirt. -- You received this message because you are subscribed to the Google Groups "neonixie-l" group. To post to this group, send an email to [email protected]. To unsubscribe from this group, send email to [email protected]. For more options, visit this group at http://groups.google.com/group/neonixie-l?hl=en-GB.