On Nov 2, 10:49 am, threeneurons <[email protected]> wrote:
[snip]
>  The result was the same. Step okay at 2mA, but stick
> anything less, let alone 350uA.
>
> Today, however, was different.

Great video of dekatron in action!  One thing to consider about neon
tubes of this nature is that ambient light can effect the striking
voltage.  I'm not saying this is your problem as you make no reference
to the voltages involved.  If you did your initial testing under
fluorescent (or low) lighting and then re-tested in sunlight, or
incandescent lighting, you may have differing results if you are
running near the striking voltage threshold.  Also, a nearby
radioactive source  (beta, gamma) can also lower the striking
threshold. (just what else are you working on in your lab ?;-)

Just my two cents as to why this may have happened.

-- 