On Aug 25, 8:53 am, "Konstantin" <[email protected]> wrote: > Thanks for your info on Electronica 7 clock, helped me a lot, as I got big > one, as a gift, and have played with it yesterday - > - one tube has been broken in transit and I have to replace it with IV-26 > type 1, as I cannot find type 2 tube, even on ebay or in Russia yet...
I've contacted all of the eBay sellers as well as the online electronic shops that claim to have Type 2, and I have either received no reply or a statement that they do not have any Type 2. Fortunately, Type 1 is quite common and with some jumpering can be used to replace Type 2 or 3. I can probably come up with one Type 2 tube (probably used) for you if you can't get a Type 1 to fit. > My clock is quite young, mage in 1998, has all features of 06K model and 11 > tubes per digit plus, looks like, there is board to display temperature, > but I have no idea what temperature sensor should be used with it... I would be very interested in pictures of the date code label as well as the temperature board and other components, along with scans of the manual (if you have it). The 12-tube manual and schematics are linked from my blog; I have an 11-tube manual / schematic from 1990 if you need that posted. > Clock transformer has 2 winds rated for 110volts connected in series, so I > believe, > it's quite simple to re-solder one wire for one wind use for 110-120Vmains, > as in USA. The winding should be paralleled, and in phase. Refer to this document from Hammond Manufacturing: http://www.hammondmfg.com/5CHook.htm The pin numbers will be different, but it should convey the needed changes. -- You received this message because you are subscribed to the Google Groups "neonixie-l" group. To post to this group, send an email to [email protected]. To unsubscribe from this group, send email to [email protected]. For more options, visit https://groups.google.com/groups/opt_out.