Though, the 4K7 is not needed, it does no harm. Even if the xstr had the minimal hfe of 25, there would be less than a 1V drop across that resistor.
I have a IN-13 running right now, on my nixie thermometer. The drawing of the pinout, is correct, from the viewed side of the tube. The aux cathode, specifies cathode, so it should be wired as shown. On Wednesday, May 18, 2016 at 10:55:22 AM UTC-7, Jon wrote: > > > OK, that's better. Your problem is the 4K7 base resistor I think - not > needed for this configuration. Base current is limited by the emitter > resistor (620R). > > Jon. > -- You received this message because you are subscribed to the Google Groups "neonixie-l" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To post to this group, send an email to [email protected]. To view this discussion on the web, visit https://groups.google.com/d/msgid/neonixie-l/1c3b0c63-af25-46c2-8ab1-dd42be36b91a%40googlegroups.com. For more options, visit https://groups.google.com/d/optout.