The 5031 has a collar around the cathode stack, and it reduces the viewing 
angle. I cant think of any reason why it would affect the operating life.

Given this is an earlier-generation nixie vs the 5092, I'm sure there were 
several improvements that Burroughs made for improving reliability and 
manufacturability. The glass-seal around the pins is ultra-critical, which 
might be a factor in shorter 5031 lifetime due to gas leaks. After 50 
years, even a leak that is undetectable will have caused some damage.

-- 