Indeed, I found they worked far better with un-smoothed 50Hz rectified 
current limited mains from a variac - putting a cap after the rectifier so 
they had smooth(er) DC made them unreliable. 
Nice to know this also works with square wave pulsed DC.

On Saturday, 29 April 2017 05:17:44 UTC+1, start end wrote:
>
> https://youtu.be/mwD-WWELFqY
>
> With DC high voltage power supply, the plasma didn't anchor to the bottom. 
> With 50Hz square wave pulse current, the tube worked correctly.
>
> There are many advantages with pulse power supply: 
> 1. Saving energy
> 2. Stabilizing the plasma 
> 3. Reducing heat emission
> 4. Preventing cathode poisoning
>

-- 
You received this message because you are subscribed to the Google Groups 
"neonixie-l" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To post to this group, send an email to [email protected].
To view this discussion on the web, visit 
https://groups.google.com/d/msgid/neonixie-l/8dee5c42-c6dd-4ba5-ac0e-9ac7bc4436af%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Reply via email to