So it looks like the cathodes are poisoned (dark areas), and where they are 
still glowing, the metal has deposited nearby.

I wonder if you can depoison them with high current, and coax the metal to 
redeposit at the bottom of the display by leaving it vertical, where the 
temperature is lowest.

-- 