Altering C5 (within wide limits) will not change whether it works or not on 
your GS10D - it just determines the speed of pulses from the neon 
relaxation oscillator. To make the dekatrons run anti-clockwise rather than 
clockwise, simply swap the G1 and G2 connections. I don't see why you 
couldn't add in a DPDT switch to make the stepping direction easily 
user-selectable.

Jon.

-- 
You received this message because you are subscribed to the Google Groups 
"neonixie-l" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To post to this group, send an email to [email protected].
To view this discussion on the web, visit 
https://groups.google.com/d/msgid/neonixie-l/b1ecaa8a-d0f9-4250-b658-a41c6ebc8fbd%40googlegroups.com.