Le Thu, 12 Jul 2007 15:39:56 -0400,
"Pete Duffin" <[EMAIL PROTECTED]> a écrit :

> It doesn't actually crash, any existing connections remain just fine. 

Established connections are not handled by inetd. 

> However, no new connections can be established.

Do you have any log message about inetd disabling failing or looping services?

> The only way to fix it is to restart inetd.

Or wait for a while (5 min)
Or send SIGHUP to inetd

I suppose...

> I have confirmed that the identify services portion is the culprit 

Probably not.

> I have disabled all of the service detection plugins, and it doesn't
> break.

Yes, of course. And the Nessus report will be useless.

_______________________________________________
Nessus mailing list
[email protected]
http://mail.nessus.org/mailman/listinfo/nessus