>>>>> On Mon, 25 Oct 2004 16:23:52 -0700, "Fong Tsui" <[EMAIL PROTECTED]> said:

Fong> For my understanding, rwcommunity/rocommunity is wrap-up for
Fong> vacm's(com2c). If I want a community to be able to read all MIB and only
Fong> to write a restrict OIDs, can this be done by specifying as follow:

Fong> rocommunity public source .1
Fong> rwcommunity public source .1.3.6.1.4.1.3375.1.0

No, that will fail.  You need to use the fuller method of using VACM
support (com2sec and beyond) to get what you want.  Doing the above
will not work.

-- 
Wes Hardaker
Sparta


-------------------------------------------------------