On Thu, 09 Sep 2010 09:49:52 -0700 Wes wrote: WH> JW> I can collect these metrics into Count32 and Count64 variables WH> JW> respectively, but management systems using these MIBs will see WH> JW> rollovers at 29 and 48. Is this acceptable? WH> WH> No, unfortunately, it is not. The management station will get skewed WH> data it doesn't expect if you do it that way. WH> [...] WH> JW> I don't think that they support odd rollover bit counts. WH> WH> The datatype for counters doesn't allow for this. It's designed for WH> 32bit only or 64bit only.
Unless the counter object in question has a discontinuity time object. Assuming the manager checks the object, which most probably don't. ------------------------------------------------------------------------------ Start uncovering the many advantages of virtual appliances and start using them to simplify application deployment and accelerate your shift to cloud computing http://p.sf.net/sfu/novell-sfdev2dev _______________________________________________ Net-snmp-coders mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/net-snmp-coders