On 1 April 2011 16:40, Singh, Vinay <vsi...@informatica.com> wrote:
> #This trap dpes not work correctly ( 64 bit varbinds) - triggers if the
> value is 0
>
> notificationEvent HaveRMSources6 DISMAN-EVENT-MIB::mteTriggerFalling -o
> TNW-MIB::tnwSourceLbtrmAggNaksRcved
>
> monitor -e HaveRMSources6 -r 10 RMSource6
> TNW-MIB::tnwSourceLbtrmAggNaksRcved  0 10


As far as I can tell, the DisMan Event MIB was designed for
use with 32-bit values only.   I don't believe it's possible to
monitor 64-bit counters using this MIB.

Note that the value objects - mteTriggerBooleanValue,
mteTriggerThresholdRising, etc  are defined using the
syntax  Integer32 so it's not really possible to compare
these against 64-bit counter objects.

Dave

------------------------------------------------------------------------------
Create and publish websites with WebMatrix