Thank you Dave, That worked out great,
I added the following to snmpd.conf
interface    eth0     6    1000000000
interface    eth1     6    1000000000
interface    eth2     6    1000000000
interface    eth3     6    1000000000
interface    eth4     6    1000000000
interface    eth5     6    1000000000

Have a great day.

On 5/9/07, Dave Shield <[EMAIL PROTECTED]> wrote:
> On 09/05/07, Robert M <[EMAIL PROTECTED]> wrote:
> > Can anyone point me in the right direction to modify the server to
> > report the correct speeds of the ethernet cards ?
>
> Quick 'n dirty fix.
> See FAQ entry:
>      The speed/type of my network interfaces is wrong - how can I fix it?
>            http://www.net-snmp.org/wiki/index.php/FAQ:Agent_35
>
> If you want to fix this "properly", then have a look at the routine
>      netsnmp_linux_interface_get_if_speed()
> (in if-mib/data_access/interface_linux.c)
>
> and try a simple test program using the relevant ioctl calls.
> But the snmpd.conf file is the easiest way to have the agent return the
> correct information.
>
> Dave
>


-- 
With regards,

RobertMCol

-------------------------------------------------------------------------
This SF.net email is sponsored by DB2 Express
Download DB2 Express C - the FREE version of DB2 express and take
control of your XML. No limits. Just data. Click to get it now.
http://sourceforge.net/powerbar/db2/
_______________________________________________
Net-snmp-users mailing list
[email protected]
Please see the following page to unsubscribe or change other options:
https://lists.sourceforge.net/lists/listinfo/net-snmp-users

Reply via email to