2009/8/11 Michal Filka <[email protected]>:
>> 2009/8/11 Michal Filka <[email protected]>:
>> > monitor -e <notif_event>  -r 60 "xxxx" myMIB::Value > 0
>> > monitor -e <notif_event>  -r 60 "xxxx" != myMIB::Value
>>
>> Is the token "xxxx" the same for both lines?
> ... Names are different but 8 first letters is same

The trigger name can be up to 32 characters,
so as long as they're different, that should be OK.

Try running the agent with *just* the second one.
Does it work or not?
Is anything logged by the agent?

Try starting the agent with the flag '-Ddisman'
Does the debug output show anything relevant?

Dave

------------------------------------------------------------------------------