Hi,
Startup(coldstart/shutdown) are default traps from snmpDaemon (start/stop)
When snmpDaemon start/stop , it sends out coldstart/shutdown traps and they
are builtin.
There is no option to disable them, You have to comment code which
sending stratup traps in net-snmp source code.
How did you enabled traps for physical sensors?
Thank you
On Sat, Jun 17, 2017 at 3:52 PM, Siddhant Gupta <dpsrkp....@gmail.com>
wrote:
> I am writing an application for a switch that uses net-snmp. I wrote my
> version of ifTable_data_access.c. Whenever I restart or start net-snmp a
> cold-start trap is sent out followed by link up/down traps for all the
> ports. Why is this happening? I have enabled traps for Physical sensors
> also, however I receive traps only for link up down.
>
> ------------------------------------------------------------
> ------------------
> Check out the vibrant tech community on one of the world's most
> engaging tech sites, Slashdot.org! http://sdm.link/slashdot
> _______________________________________________
> Net-snmp-users mailing list
> Net-snmp-users@lists.sourceforge.net
> Please see the following page to unsubscribe or change other options:
> https://lists.sourceforge.net/lists/listinfo/net-snmp-users
>
>
------------------------------------------------------------------------------
Check out the vibrant tech community on one of the world's most
engaging tech sites, Slashdot.org! http://sdm.link/slashdot
_______________________________________________
Net-snmp-users mailing list
Net-snmp-users@lists.sourceforge.net
Please see the following page to unsubscribe or change other options:
https://lists.sourceforge.net/lists/listinfo/net-snmp-users