From: Sudarsana Reddy Kalluru <[email protected]> Time Sync (PTP) implementation uses the divisor/shift value for converting the clock ticks to nanoseconds. Driver currently defines shift value as 1, this results in the nanoseconds value to be calculated as half the actual value. Hence the user application fails to synchronize the device clock value with the PTP master device clock. Need to use the 'shift' value of 0.
Signed-off-by: Sony.Chacko <[email protected]> Signed-off-by: Sudarsana Reddy Kalluru <[email protected]> Signed-off-by: Yuval Mintz <[email protected]> --- drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c index 20fe6a8..0cee4c0 100644 --- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c +++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c @@ -15241,7 +15241,7 @@ static void bnx2x_init_cyclecounter(struct bnx2x *bp) memset(&bp->cyclecounter, 0, sizeof(bp->cyclecounter)); bp->cyclecounter.read = bnx2x_cyclecounter_read; bp->cyclecounter.mask = CYCLECOUNTER_MASK(64); - bp->cyclecounter.shift = 1; + bp->cyclecounter.shift = 0; bp->cyclecounter.mult = 1; } -- 1.8.3.1