On Tue, Nov 29, 2016 at 05:05:20PM +0100, Tobias Brunner wrote:
> When handling inbound packets, the two halves of the sequence number
> stored on the skb are already in network order.
> 
> Fixes: 7021b2e1cddd ("esp4: Switch to new AEAD interface")
> Signed-off-by: Tobias Brunner <[email protected]>

Acked-by: Herbert Xu <[email protected]>

Thanks for catching this!
-- 
Email: Herbert Xu <[email protected]>
Home Page: http://gondor.apana.org.au/~herbert/
PGP Key: http://gondor.apana.org.au/~herbert/pubkey.txt