The internal PHYs of the mv88e6390 do not have a model ID. Trap any
calls to the ID register, and if it is zero, return the ID for the
mv88e6390. The Marvell PHY driver can then bind to this ID.

Signed-off-by: Andrew Lunn <and...@lunn.ch>
---
 drivers/net/dsa/mv88e6xxx/chip.c | 8 ++++++++
 1 file changed, 8 insertions(+)

diff --git a/drivers/net/dsa/mv88e6xxx/chip.c b/drivers/net/dsa/mv88e6xxx/chip.c
index bf385377a461..29190303ace0 100644
--- a/drivers/net/dsa/mv88e6xxx/chip.c
+++ b/drivers/net/dsa/mv88e6xxx/chip.c
@@ -2930,6 +2930,14 @@ static int mv88e6xxx_mdio_read(struct mii_bus *bus, int 
phy, int reg)
        err = chip->info->ops->phy_read(chip, bus, phy, reg, &val);
        mutex_unlock(&chip->reg_lock);
 
+       if (reg == MII_PHYSID2) {
+               /* Some internal PHYS don't have a model number.  Use
+                * the mv88e6390 family model number instead.
+                */
+               if (!(val & 0x3f0))
+                       val |= PORT_SWITCH_ID_PROD_NUM_6390;
+       }
+
        return err ? err : val;
 }
 
-- 
2.11.0