On Mon, Sep 11, 2017 at 12:32:10PM +0000, [email protected] wrote:
> From: Nisar Sayed <[email protected]>
>
> Configure pause time to 0xffff when tx flow control enabled
>
> Set pause time to 0xffff in the pause frame to indicate the
> partner to stop sending the packets. When RX buffer frees up,
> the device sends pause frame with pause time zero for partner to
> resume transmission.
Hi Nisar
Thanks for the updated description. Since you are posting this for
net, not net-next, could you add a fixes: tag?
Thanks
Andrew