Please correct me if I'm wrong, but...
It looks like Eran's proposed fix would remove all warning and
alarm indications from ethtool's output. It's worth mentioning
that for me, the following fields always reported correctly
as Off while no alarm condition was present
and On while alarm condition(s) were present
*per the QSFP's true/programmed threshold values*
*not per the incorrectly reported threshold values*

         Laser bias current high alarm   (Chan 1)  : Off
         Laser bias current low alarm    (Chan 1)  : Off
         Laser bias current high warning (Chan 1)  : Off
         Laser bias current low warning  (Chan 1)  : Off
         Laser bias current high alarm   (Chan 2)  : Off
         Laser bias current low alarm    (Chan 2)  : Off
         Laser bias current high warning (Chan 2)  : Off
         Laser bias current low warning  (Chan 2)  : Off
         Laser bias current high alarm   (Chan 3)  : Off
         Laser bias current low alarm    (Chan 3)  : Off
         Laser bias current high warning (Chan 3)  : Off
         Laser bias current low warning  (Chan 3)  : Off
         Laser bias current high alarm   (Chan 4)  : Off
         Laser bias current low alarm    (Chan 4)  : Off
         Laser bias current high warning (Chan 4)  : Off
         Laser bias current low warning  (Chan 4)  : Off
         Module temperature high alarm             : Off
         Module temperature low alarm              : Off
         Module temperature high warning           : Off
         Module temperature low warning            : Off
         Module voltage high alarm                 : Off
         Module voltage low alarm                  : Off
         Module voltage high warning               : Off
         Module voltage low warning                : Off
         Laser tx power high alarm   (Channel 1)   : Off
         Laser tx power low alarm    (Channel 1)   : Off
         Laser tx power high warning (Channel 1)   : Off
         Laser tx power low warning  (Channel 1)   : Off
         Laser tx power high alarm   (Channel 2)   : Off
         Laser tx power low alarm    (Channel 2)   : Off
         Laser tx power high warning (Channel 2)   : Off
         Laser tx power low warning  (Channel 2)   : Off
         Laser tx power high alarm   (Channel 3)   : Off
         Laser tx power low alarm    (Channel 3)   : Off
         Laser tx power high warning (Channel 3)   : Off
         Laser tx power low warning  (Channel 3)   : Off
         Laser tx power high alarm   (Channel 4)   : Off
         Laser tx power low alarm    (Channel 4)   : Off
         Laser tx power high warning (Channel 4)   : Off
         Laser tx power low warning  (Channel 4)   : Off
         Laser rx power high alarm   (Channel 1)   : Off
         Laser rx power low alarm    (Channel 1)   : Off
         Laser rx power high warning (Channel 1)   : Off
         Laser rx power low warning  (Channel 1)   : Off
         Laser rx power high alarm   (Channel 2)   : Off
         Laser rx power low alarm    (Channel 2)   : Off
         Laser rx power high warning (Channel 2)   : Off
         Laser rx power low warning  (Channel 2)   : Off
         Laser rx power high alarm   (Channel 3)   : Off
         Laser rx power low alarm    (Channel 3)   : Off
         Laser rx power high warning (Channel 3)   : Off
         Laser rx power low warning  (Channel 3)   : Off
         Laser rx power high alarm   (Channel 4)   : Off
         Laser rx power low alarm    (Channel 4)   : Off
         Laser rx power high warning (Channel 4)   : Off
         Laser rx power low warning  (Channel 4)   : Off


I would like to request that any fix keeps the above information
included in the ethtool -m output because it is working and valuable.

The only values that report incorrectly can be seen
by issuing the command:
ethtool -m interfaceXXX | grep  threshold

Ideally, any fix would display the thresholds correctly
instead of omit them.


Thank you and best regards,
Chris