On Thu, Jan 10, 2019 at 01:54:16PM -0800, David Miller wrote:
> From: Andrew Lunn <[email protected]>
> Date: Wed, 9 Jan 2019 00:24:03 +0100
>
> > The 6390 copper ports have an errata which require poking magic values
> > into undocumented magic registers and then performing a software
> > reset.
> >
> > Signed-off-by: Andrew Lunn <[email protected]>
>
> Applied, thanks Andrew.
>
> Would you like me to queue this up for -stable.
Hi David
Ah, sorry, i marked it for net, but did not add a fixes tag. Yes,
please add it to -stable.
I'm not sure there is a good fixed-tag, since this is an errata.
Thanks
Andrew