From: Yangbo Lu <[email protected]> Date: Mon, 27 Jul 2020 18:26:14 +0800
> From: laurent brando <[email protected]> > > The next hw timestamp should be snapshoot to the read registers > only once the current timestamp has been read. > If none of the pending skbs matches the current HW timestamp > just gracefully flush the available timestamp by reading it. > > Signed-off-by: laurent brando <[email protected]> > Signed-off-by: Vladimir Oltean <[email protected]> > Signed-off-by: Yangbo Lu <[email protected]> Applied and queued up for -stable, thanks. So you have to read the hwtimestamp, even if you won't use it for any packets?