Send Netdot-users mailing list submissions to
        [email protected]

To subscribe or unsubscribe via the World Wide Web, visit
        https://osl.uoregon.edu/mailman/listinfo/netdot-users
or, via email, send a message with subject or body 'help' to
        [email protected]

You can reach the person managing the list at
        [email protected]

When replying, please edit your Subject line so it is more specific
than "Re: Contents of Netdot-users digest..."


Today's Topics:

   1. Unable to pull SNMP for Alcatel Lucent Omni Switches
      (Kuse, Frank, Vodafone Ghana)
   2. Re: Unable to pull SNMP for Alcatel Lucent Omni   Switches
      (Carlos Vicente)


----------------------------------------------------------------------

Message: 1
Date: Fri, 19 Feb 2016 17:12:05 +0000
From: "Kuse, Frank, Vodafone Ghana" <[email protected]>
Subject: [Netdot-users] Unable to pull SNMP for Alcatel Lucent Omni
        Switches
To: "[email protected]" <[email protected]>
Message-ID:
        
<e741e3495bfc5e41adddcdb051f2a2500d8b2...@voexm26w.internal.vodafone.com>
        
Content-Type: text/plain; charset="us-ascii"

Hello All,

I am setting up NetDot for our Vodafone Ghana network and currently is unable 
to pull SNMP properties for Alcatel lucent OmniSwitches.

We have the variant of 6850, 6850-E and 9600 types devices for the switches.

Any direction on how I can  get the SNMP mibs and setting up of the Site.conf 
configuration file to help pull this nodes is appreciated.

Regards,

Frank
-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
http://osl.uoregon.edu/pipermail/netdot-users/attachments/20160219/625597fa/attachment-0001.html
 

------------------------------

Message: 2
Date: Fri, 19 Feb 2016 14:37:21 -0500
From: Carlos Vicente <[email protected]>
Subject: Re: [Netdot-users] Unable to pull SNMP for Alcatel Lucent
        Omni    Switches
To: "Kuse, Frank, Vodafone Ghana" <[email protected]>
Cc: "[email protected]" <[email protected]>
Message-ID: <[email protected]>
Content-Type: text/plain; charset=us-ascii

Hello Frank,

On Feb 19, 2016, at 12:12 PM, Kuse, Frank, Vodafone Ghana 
<[email protected]> wrote:

> Hello All,
>  
> I am setting up NetDot for our Vodafone Ghana network and currently is unable 
> to pull SNMP properties for Alcatel lucent OmniSwitches.
>  
> We have the variant of 6850, 6850-E and 9600 types devices for the switches.
>  


Can you be more specific? Does that mean that Netdot cannot connect via SNMP, 
or that it does, and there is information that is missing?


> Any direction on how I can  get the SNMP mibs and setting up of the Site.conf 
> configuration file to help pull this nodes is appreciated.
>  

All the SNMP support is handled by the SNMP::Info Perl library, which is a 
separate project. 

http://search.cpan.org/~oliver/SNMP-Info/Info.pm

Cheers,

cv




------------------------------

_______________________________________________
Netdot-users mailing list
[email protected]
https://osl.uoregon.edu/mailman/listinfo/netdot-users


End of Netdot-users Digest, Vol 83, Issue 8
*******************************************

Reply via email to