Hello
notification 'hardware-state-oper-enabled', notification
'hardware-state-oper-disabled' contains leaf admin-state, alarm-state
referring to path "/hardware/component/state/admin-state" ,
"/hardware/component/state/alarm-state" but not specifying instance of hardware
component
Should this be changed to "/hardware/component[name =
current()/../name]/state/admin-state","/hardware/component[name =
current()/../name]/state/alarm-state" so that it is in-line with the notation
shown in RFC7950 examples?
RFC-8348 Example
notification hardware-state-oper-disabled {
leaf name {
type leafref {
path "/hardware/component/name";
}
leaf admin-state {
type leafref {
path "/hardware/component/state/admin-state";
}
leaf alarm-state {
type leafref {
path "/hardware/component/state/alarm-state";
}
}
RFC7950 indicates to refer instance in page 162, 160
Page 162
The following notification defines two leafrefs to refer to an existing
admin-status:
notification link-failure {
leaf if-name {
type leafref {
path "/interface/name";
}
}
leaf admin-status {
type leafref {
path "/interface[name = current()/../if-name]"
+ "/admin-status";
}
}
Page 160
The following leafrefs refer to an existing address of an interface:
container default-address {
leaf ifname {
type leafref {
path "../../interface/name";
}
}
leaf address {
type leafref {
path "../../interface[name = current()/../ifname]"
+ "/address/ip";
}
}
}
Regards,