By design, if you choose the same option more than once the last one takes effect. Support for more than one interval type is not available at this time. You may try using logrotate or a script to aid or send a patch.
On Wed, Feb 5, 2014 at 3:43 PM, <[email protected]> wrote: > Hi, > > I would like to have netsniff-ng rotate the capture file if a particular > time has passed or a particular size has been reached. > > The options are: --interval 60sec --interval 10MiB > > The full line is: > > /usr/sbin/netsniff-ng -V --silent --in em1 --filter icmp and host x.x.x.x > --ring-size 25MiB --interval 60sec --interval 10MiB --prefix eth1. --out > /var/opt/capture/ --bind-cpu 4 > > > It seems to be taking the size and not the time when rotating. > > I use a similar thing on tshark and I am trying to duplicate it here. > > Ideas? > > Thanks in advance! > > John > > -- > You received this message because you are subscribed to the Google Groups > "netsniff-ng" group. > To unsubscribe from this group and stop receiving emails from it, send an > email to [email protected]. > For more options, visit https://groups.google.com/groups/opt_out. > -- Jon Schipp, jonschipp.com, sickbits.net -- You received this message because you are subscribed to the Google Groups "netsniff-ng" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. For more options, visit https://groups.google.com/groups/opt_out.