On 10/18/06, Michael Watz <[EMAIL PROTECTED]> wrote:
Wondering if anyone else has heard of this problem - with jumbo frames enabled
on an ipge interface (Solaris 10 SPARC), the CRS is unable to communicate
between nodes. We disabled the jumbo frames and the RAC installation worked
fine.
Does anyone know or have any experience with this problem?
Do you have jumbo frames enabled on the ethernet switch that the
servers are connected to? If there are multiple switches involved, be
sure that jumbo frames are enabled between the switches as well.
In some environments that I have worked on, enabling jumbo frames was
essential to get the required performance.
Mike
--
Mike Gerdts
http://mgerdts.blogspot.com/
_______________________________________________
networking-discuss mailing list
[email protected]