Hi,

'man rge' states, among the rest, 
.....
     The  values  returned  by  the  driver  in the DL_INFO_ACK primitive in
       response to the DL_INFO_REQ are as follows:

           o      Maximum SDU (with jumbo frame) is 7000.

           o      Minimum SDU is 0.
.....

The hardware apparently supports it; I am using Jumbo frames on three NetBSD 
machines with the same network adapter; it only warns that the max is 7500, not 
9000 as expected:

 $ ifconfig re0
re0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 7500
        
capabilities=3f80<TSO4,IP4CSUM_Rx,IP4CSUM_Tx,TCP4CSUM_Rx,TCP4CSUM_Tx,UDP4CSUM_Rx,UDP4CSUM_Tx>
        enabled=0
        address: 00:14:c1:4c:3a:f4
        media: Ethernet autoselect (1000baseT full-duplex)
        status: active
        inet 10.1.32.9 netmask 0xff000000 broadcast 10.255.255.255
        inet6 fe80::214:c1ff:fe4c:3af4%re0 prefixlen 64 scopeid 0x1

On OpenSolaris I get: 
 # dladm show-linkprop -p mtu rge0
LINK         PROPERTY        PERM VALUE          DEFAULT        POSSIBLE
rge0         mtu             r-   1500           1500           1500

Is there any particular reason Jumbo frames are not supported on this adapter? 


Chavdar Ivanov
-- 
This message posted from opensolaris.org