Hi again,
I'm starting to suspect that the occasional flow losses I'm seeing in 
nfsen are caused by the flow-tools flow-fanout that I placed in front of 
nfcapd. Actually, my (average) flow rate into the collector is around 
1Mbit/s (but flows come in big bursts...),  and then I had 5 internal 
fanouts on the loopback interface (so 6 Mbit/s of traffic to handle). 
Now I removed three of these five fanouts, and I'll see how it goes.

Can I ask the list:

1) if anybody using flow-fanout to duplicate flows before nfcapd had 
ever noted flow losses because of it
2) are there other flow fan-out tools that can be used? how do they 
perform? (e.g. what about samplicator? will it support v9?)

Thanks,
Maurizio


-------------------------------------------------------------------------