Thanks a lot to all of you. Regards!!!
El mar., 21 abr. 2020 a las 12:06, Giles Coochey (<gi...@coochey.net>) escribió: > > On 21/04/2020 15:45, Roberto Carna wrote: > > Hi Giles, I'll read them right now. > > > > But from nfsen side, is it possible to change 5 minutes cycle time to > > a lower value, let's say 1 minute ??? I mean the interval that Nfsen > > writes the data to the graphs. > > > > Thanks again, regards !!! > > It needs to be done on the router side. Nfsen will not know about the > flow stats until the router sends detail about it. So the timeout has to > happen on the router, you can set the value on the router to 60 seconds > if you wish to get upto the minute flow information, but Nfsen will, by > default, only update every 5 minutes anyway. > > Netflow and SNMP are two very different things, with SNMP only looking > at packet counters, whereas, Netflow providing flow information, the two > graphs will never look exactly the same. > >
_______________________________________________ Nfsen-discuss mailing list Nfsen-discuss@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/nfsen-discuss