There are several ways to do this.

Read about PARATYPE=2 in nm720.pdf

Or, instead of using psexec as the loader, use the native WINDOWS start 
command.  Here is an alternative fpiwini8.pnm using start:



$DEFAULTS

[nodes]=8

$GENERAL

NODES=[nodes] PARSE_TYPE=2 PARSE_NUM=34 TIMEOUTI=300 TIMEOUT=20000 PARAPRINT=0 
TRANSFER_TYPE=0

$COMMANDS ;each node gets a command line, used to launch the node session

1:NONE

2-[nodes]:start /B /Dworker{#-1} nonmem.exe

$DIRECTORIES

1:NONE ; FIRST DIRECTORY IS THE COMMON DIRECTORY

2-[nodes]:worker{#-1} ; NEXT SET ARE THE WORKER directories


Robert J. Bauer, Ph.D.
Vice President, Pharmacometrics, R&D
ICON Development Solutions
7740 Milestone Parkway
Suite 150
Hanover, MD 21076
Tel: (215) 616-6428
Mob: (925) 286-0769
Email: [email protected]<mailto:[email protected]>
Web: www.iconplc.com<http://www.iconplc.com/>

From: [email protected] [mailto:[email protected]] On 
Behalf Of Fisher Dennis
Sent: Monday, March 18, 2013 9:16 PM
To: [email protected]
Subject: [NMusers] command prompt windows opening with -parafile option

Colleagues,

I have been configuring parallelization in NONMEM 7.2 on several Windows 
machines for various colleagues.  I have discovered an inconsistency that I 
don't understand.

On one machine, when I start the process, 3 additional command prompt windows 
open (nodes = 4) and the task manager shows the 4 NONMEM jobs; when the 
estimation step completes, the windows close, then reopen during the covariance 
step, then close again.

On the other machine, no additional windows open and the task manager also 
shows the 4 NONMEM jobs.  The setups are otherwise identical (gfortran) with 
the same command (FPI, rather than MPI).

I don't know which is the expected behavior.  I would prefer the setup without 
the additional command prompt windows.  Is there a configuration issue that I 
can control?  Any thoughts would be appreciated.

Dennis

Dennis Fisher MD
P < (The "P Less Than" Company)
Phone: 1-866-PLessThan (1-866-753-7784)
Fax: 1-866-PLessThan (1-866-753-7784)
www.PLessThan.com<http://www.plessthan.com/>




ICON plc made the following annotations.
------------------------------------------------------------------------------
This e-mail transmission may contain confidential or legally privileged 
information
that is intended only for the individual or entity named in the e-mail address. 
If you
are not the intended recipient, you are hereby notified that any disclosure, 
copying,
distribution, or reliance upon the contents of this e-mail is strictly 
prohibited. If
you have received this e-mail transmission in error, please reply to the 
sender, so that
ICON plc can arrange for proper delivery, and then please delete the message.
Thank You,
ICON plc
South County Business Park
Leopardstown
Dublin 18
Ireland
Registered number: 145835

Reply via email to