Dear Navin Goyal,

Thanks for helping us out. It worked! We performed some clinical trial 
simulations for probability of target attainment and parameter uncertainty 
certainly made a difference.

Sincerely,

Rob

Van: Heine, Rob ter
Verzonden: maandag 11 april 2016 19:48
Aan: Navin Goyal
Onderwerp: Re: [NMusers] Some help with simulation with uncertainty using 
$PRIOR TNPRI

Dear Navin! Thank you a lot! We will try tomorrow and will keep you informed.

Sincerely,
Rob

Van: Navin Goyal <[email protected]<mailto:[email protected]>>
Datum: Monday, April 11, 2016 at 6:32 PM
Aan: Rob ter Heine <[email protected]<mailto:[email protected]>>
CC: nmusers <[email protected]<mailto:[email protected]>>
Onderwerp: Re: [NMusers] Some help with simulation with uncertainty using 
$PRIOR TNPRI

Hi Rob,

This may help. I have used the Theophylline example that comes with the NM 
installation - CONTROL5 model.

Step 1 - You execute that model with only one minor change -  addition of MSFO 
at the EST step (which generates and stores the information in the MSFI file 
you will need during simulation - step2)
$EST     MAXEVAL=450  PRINT=5 MSFO=MSFICONTROL5

Step 2- The simulation control stream is very similar to the control stream 
used for estimation. It has two $PROB sections and few extra statements, I have 
italicized the extra statements needed in the simulation step.
PS. Use the exact same initial estimates as you had in the estimation control 
stream in Step 1 (just leave them as they were in the original control stream). 
If you change the initial estimates, the simulation step will not work.

$PROB  THEOPHYLLINE   POPULATION DATA
$INPUT      ID DOSE=AMT TIME CP=DV WT
$DATA       THEOPP
$PRIOR TNPRI (PROBLEM 2) PLEV=.999 IVAR=1
$SUBROUTINES  ADVAN2
$MSFI MSFICONTROL5 ONLYREAD  ;; uses the msfi file generated during model 
fitting
$PK
   CALLFL=1
   KA=THETA(1)+ETA(1)
   K=THETA(2)+ETA(2)
   CL=THETA(3)*WT+ETA(3)
   SC=CL/K/WT
ISIM =IREP

$ERROR
   Y=F+EPS(1)

$PROBLEM Sim part
$INPUT      ID DOSE=AMT TIME CP=DV WT
$DATA       THEOPP REWIND

$THETA  (.1,3,5) (.008,.08,.5) (.004,.04,.9)
$OMEGA BLOCK(3)  6 .005 .0002 .3 .006 .4
$SIGMA  .4

$SIM (12345) ONLY NSUB=5 TRUE=PRIOR
;$EST     MAXEVAL=450  PRINT=5 MSFO=MSFICONTROL5    ;; commented out in step 2
;$COV  ;; commented out in step 2
$TABLE ISIM ID DOSE WT TIME FILE=sdtab5_uncertainty


As far as I can remember, control streams from Step 1 and 2 need to be run 
within same NM version. You cannot fit a model in version 7.1 and then simulate 
using ver 7.2 or 7.3 to use the $TNPRI option.


Good luck!
--
Navin Goyal

On Mon, Apr 11, 2016 at 9:38 AM, 
<[email protected]<mailto:[email protected]>> wrote:
Dear all,

I would like to perform a simulation (based on a finished model), incorporating 
parameter uncertainty (for all theta’s, eta’s and epsilons) with the $PRIOR 
TNPRI option in Nonmem V7.3, using the results of the covariance step as an 
input. I am still struggling how to implement this. Does anybody have an 
example control stream I could look at?

Sincerely,

Rob ter Heine

Het Radboudumc staat geregistreerd bij de Kamer van Koophandel in het 
handelsregister onder nummer 41055629.
The Radboud university medical center is listed in the Commercial Register of 